Walk-In Constant Temperature And Humidity Chamber Brs Series

Walk-In Constant Temperature And Humidity Chamber Brs Series

Walk-In Constant Temperature And Humidity Chamber Brs Series

Product use: This equipment is suitable for high and low temperature humidity test of various electronic products, aging test of LED, PCB and other products. Special requirements can be customized, such as low temperature and low humidity test: 3C/10%RH; 2, 5C/10%RH, etc. The inner box size can be customized, the temperature and humidity range can be customized, and the test room floor load-bearing capacity: 600kg/m2 (uniform load) is made of fully welded stainless steel SUS304 anti-skid plate.

共有:

Technical parameters specifications: 

1.Product Name Walk-in wet heat test chamber
Model BRS-45M³-A
2.Applicable Instructions  
2.1Scope Of Application A) This equipment is suitable for various electrical and electronic products and other products, parts and materials to conduct environmental simulation reliability tests such as high and low temperature constant and gradual changes, wet heat tests, etc.。
B) Other uses may cause personal injury and damage to equipment!
2.2Limitation Of Test Products A) Testing and storage of flammable, explosive, and volatile material samples
B) Testing and storage of corrosive material samples Testing or storage of biological samples
C) Testing and storage of samples with strong electromagnetic radiation sources
3.Volume And Size  
Effective Volume 45M³
Dimensions Of Inner Box Of Environmental Chamber W(宽)3300 mm*H(高)3000 mm*D(深)4500 mm
Dimensions Of Outer Box Of Environmental Chamber W(宽)4900mm*H(高)3380mm*D(深)5100mm(Subject to the actual product)
4.Performance
4.1 Conditions Refers to air-cooled ambient temperature at +5℃~+25℃. Relative humidity ≤85%. No-load (when there is no sample in the test chamber).
4.2 Temperature/Humidity Range 0℃ to +90℃/humidity control range 20% to 98%RH (limited temperature range, see partition diagram).
4.3 Temperature/Humidity Fluctuation ±1℃  /  ±2.5%RH
4.4 Temperature/Humidity Deviation ≤±2℃  /   A)>75%RH:≤+2,-3%RH,B)<75%RH:≤±5%RH。
4.5 Temperature Uniformity ≤±2.0℃;
4.6 Heating Rate ≤2℃/minute, average nonlinearity throughout the process, no-load
4.7 Cooling Rate ≤1℃/minute, average nonlinearity throughout the process, no-load
4.8 Heating And Cooling Overshoot ≤2℃
4.9 Maximum Load The floor surface is anti-slip plate. Load-bearing: 2000KG/m².
4.10 Trolley Equipped with a rail trolley to transport the motor in and out of the box
4.11 Noise ≤75dB (1 meter away from the unit)